language

    Back to Overview

    Danfoss EVR Refrigeration Solenoid Valve: Always a Smart Pick

    Nov 02,2026


    Danfoss
    Image Source: statics.mylandingpages.co

    Yes, the Danfoss EVR is a smart pick for most refrigeration solenoid valve applications. The series offers a broad model range, robust technical performance, wide refrigerant compatibility, strong certification coverage, and favorable total cost of ownership. These strengths hold across technical, application, compliance, and cost criteria. The global refrigeration solenoid valve market reached USD 450 million in 2024, and the EVR remains a dependable choice within it.

    Key Takeaways

    • The Danfoss EVR valve fits many refrigeration systems because it comes in many sizes and works with many refrigerants.
    • You can save money over time with the EVR because it is reliable, easy to repair, and protects your compressor.
    • The EVR meets major safety and environmental standards, so you can trust it for most commercial refrigeration jobs.

    What the EVR Refrigeration Solenoid Valve Series Offers

    Models and Configurations

    The Danfoss EVR family covers a wide application range. Engineers can select from many sizes and connection types. Coils are available for all common voltages and frequencies. A flexible parts program supports customized configuration. The lineup also includes valves optimized for R290 and CO₂. This breadth means most refrigeration solenoid valve projects can find a matching EVR variant without custom engineering.

    Key Design Features

    The series delivers precise capacity control, hot gas bypass, and liquid injection. It works with most fluorinated and environmentally friendly refrigerants. Approvals include PED, UL, LVD, and ATEX. These features combine maximum flexibility with optimum performance and efficiency.

    Strength CategoryKey Strengths of Danfoss EVR Solenoid Valve
    Model RangeBroad application coverage; wide selection of sizes and connection types; coils for all common voltages and frequencies; parts program for customized configuration; valves optimized for R290 and CO₂
    Technical PerformancePrecise capacity control, hot gas bypass, and liquid injection; compatibility with most fluorinated and environmentally friendly refrigerants; PED, UL, LVD, and ATEX approvals; maximum flexibility with optimum performance and efficiency

    Design Principles

    The EVR design follows a direct-acting or servo-operated principle, depending on the model. A guided armature and a durable seat deliver reliable opening and closing. The modular coil system allows one valve body to serve multiple voltage requirements. Service technicians can replace coils and spare parts without disturbing the piping. This modular approach simplifies inventory and speeds up maintenance across a refrigeration system.

    Technical Performance Analysis

    Capacity and Pressure Ratings

    The Danfoss EVR series delivers capacity ratings that span a wide band, from small commercial display cases to large industrial process lines. Engineers select a valve body size based on the required cooling capacity and the pressure drop across the valve. The series covers nominal capacities from roughly 0.5 kW up to several hundred kilowatts, depending on the refrigerant and operating conditions. This range allows one product family to serve many system sizes without switching to a different valve platform.

    Pressure ratings define the safe operating envelope. The EVR handles maximum working pressures that suit most modern refrigeration circuits, including systems running high-pressure refrigerants. Each valve body carries a specified maximum working pressure (MWP), and the coil and seal materials match that rating. The table below summarizes the typical performance envelope across the series.

    ParameterTypical EVR Range
    Nominal capacity~0.5 kW to several hundred kW (refrigerant-dependent)
    Maximum working pressureUp to 45 bar (model-dependent)
    Connection sizes6 mm to 54 mm (flange and solder variants)
    Coil voltage optionsAll common AC and DC voltages

    These ratings give designers a clear margin for safety and performance. A refrigeration solenoid valve must hold tight shutoff at full pressure differential, and the EVR seat and armature design support that requirement across the rated range.

    Temperature Range and Reliability

    Temperature performance separates a dependable valve from a marginal one. The EVR v2 solenoid valve carries a maximum rated media temperature of 105°C, according to Danfoss documentation. The manufacturer advises close attention to this limit in hot gas lines, hot-gas bypass lines, and hot gas supply valves for hot-gas defrosting. This published rating and the accompanying guidance show that the valve is engineered to operate reliably up to the stated 105°C threshold. Systems that push beyond this limit fall outside the validated envelope, so specifiers should confirm their worst-case media temperature before selection.

    Reliability also depends on cycle life and material stability. The guided armature moves with minimal lateral play, which reduces wear on the seat and the sealing surfaces. Seal materials resist swelling and hardening across the rated temperature band. These design choices translate into stable shutoff performance over many thousands of operating cycles. Maintenance teams report fewer nuisance leaks and fewer coil failures when the valve operates within its published limits.

    Refrigerant Compatibility

    Refrigerant compatibility determines whether a valve can serve a given system at all. The EVR series supports an unusually broad list of refrigerants, including legacy HFCs, modern HFO blends, and natural refrigerants. The EVR 3 models accept the following general refrigerants:

    • R1234yf
    • R1234ze(E)
    • R125
    • R134a
    • R152a
    • R22
    • R290
    • R32
    • R404A
    • R407A
    • R407C
    • R407F
    • R407H
    • R410A
    • R413A
    • R417A
    • R422A
    • R422B
    • R422D
    • R438A
    • R442A
    • R444B
    • R447A
    • R447B
    • R448A
    • R449A
    • R449B
    • R450A
    • R452A
    • R452B
    • R454A
    • R454B
    • R454C
    • R455A
    • R463A
    • R507A
    • R512A
    • R513A
    • R513B
    • R515A
    • R515B
    • R516A
    • R600
    • R600a

    A subset of these refrigerants also carries UL approval, including R290, R600, R600a, R32, R1234ze(E), and many of the common HFC and HFO blends. This dual coverage matters for projects that must satisfy both performance and safety certification requirements. The broad compatibility list means a single valve family can support a fleet of systems running different refrigerants, which simplifies spare parts planning and technician training. For any refrigeration solenoid valve selection, this level of refrigerant coverage reduces the risk of an incompatible match and supports long-term system flexibility.

    Where the EVR Fits Best

    Commercial Refrigeration

    Commercial refrigeration represents the EVR's core territory. Grocery stores, convenience shops, and food service operators rely on this valve to control liquid supply to display cases, walk-in coolers, and freezer rooms. The broad size range lets contractors standardize on one valve family across an entire store. A single spare parts stock then covers every circuit, which cuts inventory costs and simplifies technician training. The valve's tight shutoff also protects compressors from liquid slugging during off cycles.

    HVAC and Industrial Processes

    HVAC and industrial refrigeration processes demand precise control at low pressure differentials. The EVR handles these duties well, including liquid line shutoff and hot gas defrost. One important limit applies: the valve suits non-aggressive refrigerants and does not work with ammonia (R717). Specifiers should confirm the refrigerant before selection.

    ParameterEVR 15EVR 20
    Minimum OPD0.05 bar / 0.72 psi0.05 bar / 0.72 psi
    Liquid capacity (kv)2.6 m³/h6 m³/h
    Liquid capacity (cv)3.01 US gal/min6.9 US gal/min
    Media temperature range–40 °C to +105 °C / –40 °F to 221 °F–40 °C to +105 °C / –40 °F to 221 °F

    Real-World Installation Examples

    Field experience shows the refrigeration solenoid valve at work across many settings. Typical installations include:

    • Walk-in cold rooms
    • Display freezers and refrigerators
    • Chillers
    • Rooftops
    • Heat pumps or chillers operating in ambient temperatures up to 130°C (for hot gas defrost and bypass)
    • Food retail and commercial refrigeration

    These examples show the EVR's reach from small retail cases to large process cooling systems.

    Regulatory Compliance and Certifications

    Key Certifications

    Compliance often decides whether a refrigeration solenoid valve reaches the job site. The Danfoss EVR carries approvals that cover the major markets. Earlier sections noted PED, UL, LVD, and ATEX approvals across the series. These certifications let the valve serve pressure vessels, electrical installations, and potentially explosive atmospheres. Project teams can specify one valve family for multiple regions and reduce approval delays.

    Standards Adherence

    The EVR also meets specific safety standards for refrigeration systems. Danfoss designs and approves the EVR safety valves to the following standards:

    • UL 60335-2-40: the safety standard for electrical heat pumps, air conditioners, and dehumidifiers.
    • UL 60335-2-89: the safety standard for commercial refrigerating appliances using flammable refrigerants.

    Danfoss is proud to announce the release of its new and reliable EVR and NRV Safety Valves, approved to meet UL 60335-2-40 and UL 60335-2-89 standards.

    These approvals matter as the industry shifts toward flammable refrigerants such as R290. The UL 60335-2-89 approval confirms safe operation in systems that use these refrigerants. Specifiers gain confidence that the valve satisfies both performance and safety requirements. Compliance documentation is available for project submittals. This support shortens the approval process and helps inspectors sign off on the installation.

    Cost and Value Analysis

    Initial Cost and Availability

    The Danfoss EVR sits in the mid-to-premium price band for refrigeration solenoid valves. Buyers pay more upfront than they would for a basic commodity valve. That premium buys a proven design, a wide model range, and global distribution. Availability is a real strength. Distributors stock common sizes and coil voltages in every major market. Contractors rarely face long lead times on standard configurations. Project schedules benefit from this ready supply, and emergency repairs move faster when a replacement valve is on the shelf nearby.

    Total Cost of Ownership

    Total cost of ownership tells a more favorable story than the purchase price alone. The EVR's tight shutoff protects compressors from liquid damage. Reliable operation cuts callbacks and warranty claims. Broad refrigerant compatibility lets one valve family serve a mixed fleet, which trims inventory and training costs. Energy performance also matters. Precise capacity control keeps systems running at efficient setpoints. Over a ten-year horizon, these savings often outweigh the initial price gap against cheaper alternatives.

    Serviceability

    Serviceability shapes long-term value, and the EVR scores well here. Technicians can replace coils and internal parts without cutting pipe. The modular design keeps a single spare parts stock relevant across many valve sizes.

    ProductServiceableSpare Parts
    Danfoss EVR solenoid valve (032L7137)YesSolenoid valve spare parts available

    Fast repairs mean shorter downtime for refrigerated spaces. Stored product stays safe, and operators avoid costly spoilage events. This combination of easy service and available parts makes the EVR a practical long-term investment.

    How the EVR Compares

    Technical and Application Comparison

    The EVR family splits into two working principles. The EVR3 is direct-acting and opens at zero pressure difference. The EVR6, EVR10, EVR15, and EVR20 are servo-operated and need a minimum pressure difference to open. This split matters during selection. A system with low or variable pressure differential may favor the direct-acting EVR3. A system with stable differential and larger capacity may favor the servo models.

    Other solenoid valve types follow different design paths. An unloading solenoid valve self-loads according to heat load reduction, which suits compressor energy saving. An R410 solenoid valve is purpose-built for R410 and common refrigerants, with a defrost maximum of +130°C. A Castel solenoid valve uses a diaphragm design and serves compressor condensing units, central and bus AC, and cold storage. The table below sets out the main technical differences.

    AttributeDanfoss EVR (EVR3 direct-acting / EVR6-20 servo)Unloading Solenoid ValveR410 Solenoid ValveCastel Solenoid Valve
    Working principleEVR3: direct-acting, opens at zero pressure difference; EVR6/10/15/20: servo-operated with minimum pressure differenceSelf-loading according to heat load reductionSpecially designed for R410 refrigerantDiaphragm solenoid valve
    Applicable refrigerantsHCFC, HFCHCFC, HFCR410 and common refrigerantsGeneral refrigerants
    Media temperature range–30°C to +105°C–25°C to +105°C–40°C to +105°C (defrost max +130°C)–35°C to +105°C
    Ambient temperature–40°C to +65°CNot specified–40°C to +55°CNot specified
    Max working pressure3.5 MPa30 bar45 bar (hydraulic strength ≥68 bar)3 MPa (opening pressure 2.5/0.05 MPa)
    Working pressure differenceZero (direct-acting) / minimum required (servo)0–21 barNot specified0.05–2.5 MPa
    ApplicationsLiquid, suction, and hot gas lines in freezing, refrigeration, and ACFreezing, refrigeration, and AC (compressor energy saving)Liquid, suction, and hot gas lines in refrigeration and ACCompressor condensing units, central and bus AC, cold storage
    Coil and voltage optionsMultiple AC/DC voltages, customizable; IP65Multiple AC/DC voltages and frequenciesAC and DC, 50/60 HzNot specified
    Service lifeNot specifiedLonger working lifeNot specified100,000 cycles

    Each design has a clear technical home. The unloading valve targets compressor energy saving. The R410 valve targets R410 systems with high defrost temperatures. The Castel valve targets compact condensing and transport AC duties. The EVR covers liquid, suction, and hot gas lines across freezing, refrigeration, and AC, with a wide voltage and coil program.

    Compliance and Cost Comparison

    Purchase price varies by valve architecture. A standard solenoid valve such as the Danfoss EVR sits at the baseline and carries the lower price. A main valve such as an ICS with a pilot solenoid costs more. A motor valve (ICM) also costs more. Both higher-priced options earn their place at very low partial loads, where a standard valve may struggle. An assisted servo-controlled valve (EVRAT, EVRST) opens at a minimum pressure drop of 0 bar. That design originally served ammonia and now also works for copper refrigeration systems.

    Valve optionCost relative to standard solenoid valveNotes and applicable conditions
    Standard solenoid valve (e.g., Danfoss EVR)Baseline (lower price)Used for full-load capacities; may not suit very low partial loads
    Main valve (e.g., ICS with pilot solenoid)Higher priceGood partial-load option when standard valves cannot handle low partial loads
    Motor valve (ICM)Higher priceGood partial-load option for low partial loads
    Assisted servo-controlled valve (EVRAT, EVRST)Not specifiedMinimum pressure drop 0 bar; originally for ammonia, also usable for copper refrigeration

    Compliance comparisons rest on technical limits rather than a single regulatory scorecard. Published data for these options centers on maximum working pressure and maximum operating pressure difference (MOPD). The EVR carries PED, UL, LVD, and ATEX approvals, plus UL 60335-2-40 and UL 60335-2-89 safety approvals. Specifiers should match each valve's pressure and temperature limits to the project's refrigerant and safety requirements.

    Where Each Option Fits Best

    Application fit separates the EVR from its closest commercial rival. The EVR is purpose-designed for commercial refrigeration environments: supermarkets, convenience stores, restaurants, and cold storage rooms. Fast service, wide refrigerant coverage, and dependable cycling are essential in these settings. The valve supports liquid, suction, and hot gas line positions across a typical commercial rack. Its compatibility with the majority of fluorinated refrigerants lets a contractor standardize on one valve family across an entire store portfolio. Stocking and technician training both become simpler.

    Parker offers a different center of gravity. Its valves suit industrial plants, ammonia systems, and rugged industrial duty. Configurable flanges, a large size range, a shared coil platform, and integration with Sporlan components and defrost control support that role.

    BrandBest-fit applicationsSupporting characteristics
    Danfoss EVRCommercial refrigeration (supermarkets, convenience stores, restaurants, cold storage rooms); mixed refrigerant fleets; liquid line, suction line, and hot gas line positions on commercial racksBroad refrigerant compatibility (HFC/HFO, majority of fluorinated refrigerants); modular plug-and-play housings and weld connections without flanges; portfolio standardization across a store estate
    Parker (alternative)Industrial plants; ammonia systems; rugged industrial dutyConfigurable flanges, large size range, shared coil platform; integration with Sporlan components and defrost control

    Danfoss suits broad portfolio selection and commercial refrigeration versatility. Parker suits rugged industrial duty and ammonia support.

    The same logic applies within the Danfoss range. Standard EVR valves fit full-load capacities. Main valves and motor valves fit very low partial loads. Assisted servo-controlled valves fit systems with zero minimum pressure drop. Each option has a defined job. The EVR simply covers the widest share of everyday commercial refrigeration work.


    The Danfoss EVR remains a smart pick for most refrigeration applications. It delivers solid performance, broad application coverage, strong compliance, and good value. Choose the EVR for commercial refrigeration and mixed refrigerant fleets. Evaluate alternatives for ammonia systems or very low partial loads. This refrigeration solenoid valve covers the widest share of everyday work.

    FAQ

    Which refrigerants does the Danfoss EVR support?

    The EVR accepts most HFC, HFO, and natural refrigerants, including R134a, R404A, R448A, R449A, R290, and R600a. It does not work with ammonia (R717). Specifiers should confirm the refrigerant against the published compatibility list.

    How does a buyer choose between the EVR3 and the servo-operated models?

    The direct-acting EVR3 opens at zero pressure difference. The servo-operated EVR6, EVR10, EVR15, and EVR20 need a minimum pressure difference to open. Systems with low or variable differential favor the EVR3.

    Does the EVR suit ammonia systems?

    No. The EVR serves non-aggressive refrigerants such as HFCs, HFOs, and selected natural refrigerants. Ammonia systems require a different valve platform. Buyers should evaluate ammonia-rated alternatives for those duties.

    ICEAGE Refrigeration

    Add:  No. 615 Xiaogao west road Ningbo city, P.C. 315000, China

    Tel: (+86)- 574 - 8901 8885

    Email: market@iceage-hvac.com

    %{tishi_zhanwei}%

    © Zhejiang Haiding Cooling & Heating Technology Co., Ltd. All rights reserved.

    Powered by:

    www.300.cn